Problem:
LP360 Drone doesn’t recognize Cycle Folder. This can happen when attempting to load directly from the UMS drive or from an archive folder. The Cycle dialog will not show flight information for the cycle that the user is attempting to select. Error in LP360: The selected folder is not a valid Cycle Folder.
Import Window – Cycle Dialog
Probable Resolution #1:
The file structure requires three basic components to import a cycle properly in LP360 Drone:
- The folder name must have “Cycle_” at the beginning of the name.
- There must be a sub-folder in the cycle folder named “System”
- In the “System” folder there must be a “SystemConfiguration.json” file.
- In the “System folder there must be a “CycleParams.json” file.
Cycle folder format
If the user changes the file structure in a way where these conditions are not met, the cycle will not be visible for import.
L:\Cycle_191212_184916 | +---System | CycleParams.json | SystemConfiguration.json Example of proper file structure
Comments
0 comments
Please sign in to leave a comment.